CFD Analysis of a Triple Concentric Tube Heat Exchanger having water flowing at three different temperatures
Keywords:
Triple Concentric Tube Heat Exchanger, CFD Analysis, N- H- C ConfigurationAbstract
The present study would include heat transfer CFD analysis for a concentric triple tube heat exchanger. Theoretical studies are carried out for numerical simulations and evaluation of heat transfer. The performance of Triple Concentric Tube Heat Exchanger is to be evaluated at variable operating conditions. Studies and experimentation have already been carried out for N- H- C and C- H- N configuration in Triple Tube Heat Exchanger. The numerical investigation also has already been carried out for various operating conditions. CFD analysis is used to validate the experimental data specifically for N- H- C configuration in the present study. When the flow rate is decreased in the hot tube there is decrease in the temperature rise of the normal and cold fluids. Results are presented in graphical as well as tabular form. Tolerating small difference, CFD results are close to the experimental results.