A Study of Plan Irregularity Inducing Accidental Torsional Moment of Multi Story Building using Stadd Pro

Authors

  • Subodh.S. Patil Department of Civil Engineering, ICOER, Pune, India Author
  • Shrinivas.R. Suryawanshi Department of Civil Engineering, ICOER, Pune, India Author

DOI:

https://doi.org/10.14741/

Keywords:

Asymmetrical building, Earthquake, Torsion, Response Spectrum, Remedies on torsion &Better solution.

Abstract

In this paper sesmic performance of multistory building is check with asymmetrical plan. It observed that during
earthquake measure damage is occur at reentrant corner A g+20 and g+22 building having plan Asymmetry is
modeled in finite element analysis stadd pro v8i.Accenditial torsional load is applied with reference to 1893(part-1)-
2002.In this paper we provide artechtural relief and providing shear wall at re-entrant corner in the buildings.

References

Downloads

Published

2016-06-30

Issue

Section

Articles

How to Cite

A Study of Plan Irregularity Inducing Accidental Torsional Moment of Multi Story Building using Stadd Pro. (2016). International Journal of Current Engineering and Technology, 6(3), 853-855. https://doi.org/10.14741/